Variants per machine option
With or without a second axis, 400 V or 480 V panel, with or without a safety door. Each option changes wires, terminals and lengths; in a loose Excel and DWG, the variant is lost by the third revision.
From the cabinet from-to list to the harness that crosses the machine: schematic, 1:1 formboard, real components from Digi-Key, BOM and PDF drawings with connection tables. For machine OEMs, integrators, panel builders and robotics teams who build their own harnesses or subcontract them with a drawing that leaves no doubt.
Nothing to install · free Garage plan · your harnesses on any device
Not the complexity of an aircraft: the volume of variants, power and signal sharing the same space, and the fact that the harness is built by people other than those who designed it.
With or without a second axis, 400 V or 480 V panel, with or without a safety door. Each option changes wires, terminals and lengths; in a loose Excel and DWG, the variant is lost by the third revision.
A 400 V servo, encoder, PROFINET and 24 V I/O share trunking, carrier and sometimes a connector. EMC separation is decided at design or paid for during commissioning.
The shop crimps the harness and after-sales replaces it years later. Both need the connection table with +A1-X1:3 references, the colour and cross-section of every wire and the real length.
What should be settled before the first wire of a machine, panel, robot or energy-equipment harness is cut: which standard governs, which cable goes in each circuit, which connector survives the environment, and how it is documented so production and service read it the same way.
Two regulatory worlds coexist and many manufacturers export to both. In Europe the backbone is IEC/EN 60204-1 (electrical equipment of machines): minimum cross-sections per circuit, wiring practices (clause 13), identification and marking (clause 16) and documentation. It is the harmonised standard behind CE marking under the Machinery Directive 2006/42/EC (Regulation (EU) 2023/1230 from 2027) and the Low Voltage Directive 2014/35/EU. The switchgear the harness connects to (contactors, disconnectors, terminal blocks) falls under the IEC/EN 60947 series.
In North America the panel is built to UL 508A, and that constrains the harness even if it is made elsewhere: internal wire of a recognised type (MTW, THHN or AWM under UL 758), cross-sections from the UL 508A tables rather than IEC, connectors recognised under UL 1977 and terminal blocks under UL 1059; sheathed flexible cords under UL 62 and its CSA equivalent. For the harness as an assembled product, acceptance is agreed to IPC/WHMA-A-620: class 2 in machinery, class 3 where failure is critical (life support, parts of the energy sector). The class is set by the customer and written on the drawing.
Two more layers. Safety circuits (emergency stop, doors, light curtains) are designed to ISO 13849-1 (PL a-e) or IEC 62061 (SIL 1-3), and that reaches the harness: two channels in separate conductors, OSSD outputs with test pulses that detect cross-faults, and a route where a single mechanical damage cannot affect both; the push-button follows ISO 13850. In materials, RoHS and REACH touch PVC and contact platings; and if the equipment goes into rail, EN 45545-2 demands fire behaviour and low smoke by hazard level (HL1-HL3), which rules out ordinary PVC and leads to EN 50264 or EN 50306 cables.
Wire is chosen by voltage, temperature, environment and, increasingly, by movement.
| Cable | Standard | Voltage · temperature | Insulation | Typical use |
|---|---|---|---|---|
| UL 1007 / 1569 | UL 758 (AWM), CSA | 300 V · 80 / 105 °C | PVC | Internal signal and control, 16-30 AWG |
| UL 1015 | UL 758 (AWM), CSA | 600 V · 105 °C | Thick-wall PVC | Power and mains in panels, 8-24 AWG |
| UL 1061 | UL 758 (AWM) | 300 V · 80 °C | Semi-rigid PVC, thin wall | Dense harnesses, IDC |
| UL 3266 / 3271 | UL 758 (AWM) | 300 / 600 V · 125 °C | XLPE | Hot zones, next to heaters and motors |
| H05V-K / H07V-K | HAR, EN 50525 | 300/500 V / 450/750 V · 70 °C | PVC | Cabinet wiring in Europe; H07V2-K reaches 90 °C |
| LiYY / LiYCY | Manufacturer spec (VDE) | ≈ 300 V · 70-80 °C | PVC; LiYCY with tinned braid | Control and signal outside the cabinet |
| Servo / encoder | Drive manufacturer spec | 600/1000 V · 80-90 °C | Shielded, PUR for carriers | Motor, brake, resolver, encoder |
| Fieldbus | IEC 61158 and bus profile | Per bus | PROFINET green 22 AWG · EtherCAT Cat 5e · PROFIBUS violet 150 Ω · CAN 120 Ω · IO-Link 3-wire | Communications, with their impedance and shield |
Cross-section is stated in AWG in the UL world and in mm² in IEC; one convention is fixed per project so that 1.5 mm² and 16 AWG never share a drawing. IEC 60204-1 gives minimum cross-sections per function; the permissible current depends on bundling and cabinet temperature, not just on rated current. Servo cable is chosen by the capacitance per metre the drive tolerates: more capacitance, more leakage current and trips. For cable carriers the manufacturer declares a minimum bend radius and a cycle life (millions) for fine-stranded copper with a core filler and PUR sheath; fixed-installation cable is not designed for that.
On colours, IEC 60204-1 §13.2 mandates green-and-yellow for the protective conductor and light blue for the neutral, and recommends a code that almost all of European industry follows: black for AC and DC power, red for AC control, blue for DC control and orange for circuits that stay live when the main disconnect is opened. Another code is admissible if it is stated in the schematic. UL 508A uses a different convention (yellow for circuits fed from outside the panel), so a harness for both markets calls for an explicit decision.
Then there is the choice between single wires and sheathed multicore. In slotted trunking inside the cabinet, single wires win: they can be reassigned, identified and sized circuit by circuit. Outside the cabinet or in moving sections, multicore is better protected and passes cleanly through a cable gland. Almost every machine carries both, joined at terminal blocks or a rectangular connector.
A machine harness touches four connector scales: field, cabinet, power and board.
| Family | Examples | IP | Typical current | Use |
|---|---|---|---|---|
| Miniature circular | M8 (3-4 pins), M12 A-coded | IP67; IP69K washdown | ≈ 3-4 A | Sensors, actuators, IO-Link, valves |
| Circular data | M12 D (100 Mbit/s), M12 X (1 Gbit/s), M12 B (PROFIBUS) | IP67 | Signal | PROFINET, EtherNet/IP, EtherCAT, cameras |
| Circular power | M12 L / S / T / K, M23, M40 | IP67 | M12 L up to 16 A; M23 tens of A; M40 large servos | Field power, servomotors; M23 signal for encoders |
| Industrial rectangular | Harting Han A / E / Q / Modular; Phoenix Contact Heavycon; Weidmüller RockStar | IP65 with hood; IP68/69K in specific ranges | Han E 16 A per contact; modules up to 200 A | Pluggable cabinet-to-machine harness; power + signal + bus + pneumatics |
| DIN-rail terminal blocks | Phoenix Contact PT (push-in), Weidmüller A-series, Wago TOPJOB S | Inside the cabinet | By cross-section, 0.14 to 35 mm² and above | Boundary between internal harness and field |
| PCB connectors | Molex Mini-Fit Jr. (4.2 mm), Micro-Fit 3.0; JST XH / PH / VH; TE AMP Mate-N-Lok | No IP | Mini-Fit Jr. 9-13 A; Micro-Fit 5 A; JST XH 3 A, PH 2 A, VH 10 A | Control electronics, HMI, PSUs, medical and laboratory equipment |
| DC and battery power | Anderson SB50 to SB350, Powerpole; Amphenol SurLok, RADSOK | By housing | 15 A to hundreds of A | AGVs, industrial and agricultural vehicles, renewables |
| Ribbon and IDC | 1.27 mm ribbon with 2.54 mm IDC | No IP | ≈ 1 A per way | Boards, displays, membrane keypads |
In M12 the coding keys are mechanically different: A for sensors and IO-Link, D for 100 Mbit/s Ethernet with 4 pins, X for Gigabit with 8 pins and individually shielded pairs, and L, S, T or K for power; IP69K only makes sense with pressure washdown (food, pharma). In Harting Han the insert sets poles and current (Han E is the workhorse: 16 A, up to 48 poles; Han A is compact; Han Q packs power into few poles; Han-Modular takes power, signal, RJ45, coaxial, fibre or pneumatic modules in the same housing), while the housing (3A to 24B) and hood set IP rating, cable exit and locking. Push-in terminal blocks accept ferruled wire without a tool, which makes crimping DIN 46228 ferrules the most repeated operation on a cabinet harness; spade and ring terminals call for a calibrated crimper and a pull test. Cable glands set the real IP of the assembly: an IP67 M12 on a box with the wrong gland leaves the box at IP54. Hybrid connectors (power and data in one cable) shrink the harness but tie the design to one manufacturer.
Inside the cabinet the harness runs in lidded slotted trunking, not overfilled. Towards the machine the usual choices are polyamide corrugated conduit (PA6, typically -40 to +105 °C, oil-resistant), PET braided sleeving (abrasion, no IP), spiral wrap for sections that must be opened, heat-shrink 2:1 or 3:1 with adhesive at exposed connector exits, and UV-stabilised cable ties with mounts outdoors.
The cable carrier has rules of its own: respect the minimum radius of the most demanding cable, leave clearance around each cable, distribute weight symmetrically, separate power and signal with dividers and fix the cables only at both ends, never in the flexing section. EMC separation follows the same logic across the machine: power and signal in separate trunking, crossings at 90°, servo, encoder and bus shields terminated over 360° with EMC clamps on an earth bar at the cabinet entry, never as a pigtail, and a functional earth made with flat bar or braid. At cabinet doors the harness crosses the hinge with excess length, protected by spiral or conduit, and with its own green-and-yellow bonding conductor.
IEC 60204-1 requires every conductor to be identifiable at both ends in accordance with the technical documentation. In machinery this is solved with wire marking by number or by function, identical at both ends and in the schematic: printed heat-shrink sleeves for wires going to connectors, clip-on markers (Partex type) and self-laminating labels for sheathed cables, printed with Brady, Phoenix Contact (Thermomark) or Weidmüller (PrintJet) systems that read the project's wire list. Terminal, device and connector references follow IEC 81346 (clause 16 of 60204-1). Regulated equipment adds lot traceability: harness serial number, cable and terminal lot, operator and date, kept with the drawing revision.
It starts with the connection diagram or the from-to list: every wire with origin, destination, cross-section, colour and function, using device references to IEC 81346 (for example +A1-X1:3: cabinet A1, terminal strip X1, terminal 3). Lengths come from the cabinet and machine layout: the real run through trunking with the excess at doors and carriers, not straight-line distance. From that the 1:1 formboard is built so the shop cuts, marks and tapes without measuring each wire.
Minimum verification is continuity and absence of crosses against the connection table; for mains circuits, dielectric strength and insulation; for safety, separated channels. Revision control is tied to the machine's: every commercial option is a harness variant with its own drawing and every change bumps the revision in the title block. Documentation has two readers: production wants the formboard, cut list and BOM; after-sales wants the connection table readable at the machine, because ten years later someone will replace a sensor without the designer at hand.
harnessPRO documents the harness; electrical calculation and cross-section choice remain the engineer's job.
Place the cabinet Han, the field M12s, the terminal strips and the splices; connect wire by wire with cross-section, IEC 60204-1 colour and device tag.
Load the cabinet or machine drawing as a background, place the branch points and route the harness along its real path with the door and carrier excess.
Bring connectors and terminals from Digi-Key or the library, import pinouts, add cable, sleeving and ferrules. Export the BOM to CSV or Excel.
Generate the PDF with title block, connection table and lengths; save one revision per machine option and share the account with the shop.
In Europe, IEC/EN 60204-1 (electrical equipment of machines): minimum cross-sections, conductor identification, colours, wiring practices and documentation, harmonised for CE marking. The harness as a product is accepted to IPC/WHMA-A-620 in the class the customer specifies. If the machine ships to North America, the panel is built to UL 508A with wire of a recognised type (AWM under UL 758, MTW, THHN).
It mandates green-and-yellow for the protective conductor and light blue for the neutral. For the rest it recommends, without requiring: black for AC and DC power, red for AC control, blue for DC control and orange for circuits that stay live when the main disconnect is opened. Whichever code you choose must be documented in the schematic.
A for sensors, actuators and IO-Link (3 to 12 pins). B for PROFIBUS DP. D for 100 Mbit/s industrial Ethernet (PROFINET, EtherNet/IP, EtherCAT), 4 pins. X for Gigabit, 8 pins with individually shielded pairs. L, S, T and K codings are for power. The mechanical keys differ and are not interchangeable.
Han E is the workhorse in machinery: 16 A per contact, 6 to 48 poles. Han A is more compact, for a few signals. Han Q packs power into few poles, for example a motor with brake. Han-Modular mixes power, signal, bus, pneumatic or fibre modules in one housing. The housing (3A to 24B) and hood set the IP rating and the locking.
Cable designed for continuous motion: fine-stranded copper in short lay lengths, a core filler, PUR sheath, a minimum bend radius and a cycle life declared by the manufacturer (millions). Servo and encoder cables must also be shielded and within the capacitance the drive accepts. A standard H05V-K or LiYY does not survive continuous flexing.
Inside the cabinet, in slotted trunking, single wires: they can be reassigned, identified and sized circuit by circuit. Outside the cabinet or in moving sections, sheathed multicore (LiYCY, servo cable, bus cable): better protected and clean through a cable gland. Almost every machine carries both, joined at terminal blocks or a Han connector.
Yes. Schematic with multipole connectors, terminals, splices and twisted pairs; 1:1 Layout as a formboard with branch points and a background image of the cabinet drawing to take lengths from; real components (M12, Han, Molex) from Digi-Key or by importing the manufacturer's pinout; BOM to CSV/Excel and PDF drawings with connection tables; revisions per machine variant. It documents cross-sections and lengths, but does no electrical or thermal calculation.
Free Garage plan: 3 harnesses and 50 connections per harness, nothing to install. Pro and Team when the shop floor joins you. Prices include tax.