Machinery · Panels · Robotics · Energy

Industrial wire harness design

From the cabinet from-to list to the harness that crosses the machine: schematic, 1:1 formboard, real components from Digi-Key, BOM and PDF drawings with connection tables. For machine OEMs, integrators, panel builders and robotics teams who build their own harnesses or subcontract them with a drawing that leaves no doubt.

Nothing to install · free Garage plan · your harnesses on any device

The challenges

What makes a machine harness hard

Not the complexity of an aircraft: the volume of variants, power and signal sharing the same space, and the fact that the harness is built by people other than those who designed it.

01

Variants per machine option

With or without a second axis, 400 V or 480 V panel, with or without a safety door. Each option changes wires, terminals and lengths; in a loose Excel and DWG, the variant is lost by the third revision.

02

Power, signal and bus on the same route

A 400 V servo, encoder, PROFINET and 24 V I/O share trunking, carrier and sometimes a connector. EMC separation is decided at design or paid for during commissioning.

03

Production and service without the designer

The shop crimps the harness and after-sales replaces it years later. Both need the connection table with +A1-X1:3 references, the colour and cross-section of every wire and the real length.

Technical guide

Wire harnesses for machinery and panels: standards, cable, connectors and process

What should be settled before the first wire of a machine, panel, robot or energy-equipment harness is cut: which standard governs, which cable goes in each circuit, which connector survives the environment, and how it is documented so production and service read it the same way.

Standards that apply to machine wiring

Two regulatory worlds coexist and many manufacturers export to both. In Europe the backbone is IEC/EN 60204-1 (electrical equipment of machines): minimum cross-sections per circuit, wiring practices (clause 13), identification and marking (clause 16) and documentation. It is the harmonised standard behind CE marking under the Machinery Directive 2006/42/EC (Regulation (EU) 2023/1230 from 2027) and the Low Voltage Directive 2014/35/EU. The switchgear the harness connects to (contactors, disconnectors, terminal blocks) falls under the IEC/EN 60947 series.

In North America the panel is built to UL 508A, and that constrains the harness even if it is made elsewhere: internal wire of a recognised type (MTW, THHN or AWM under UL 758), cross-sections from the UL 508A tables rather than IEC, connectors recognised under UL 1977 and terminal blocks under UL 1059; sheathed flexible cords under UL 62 and its CSA equivalent. For the harness as an assembled product, acceptance is agreed to IPC/WHMA-A-620: class 2 in machinery, class 3 where failure is critical (life support, parts of the energy sector). The class is set by the customer and written on the drawing.

Two more layers. Safety circuits (emergency stop, doors, light curtains) are designed to ISO 13849-1 (PL a-e) or IEC 62061 (SIL 1-3), and that reaches the harness: two channels in separate conductors, OSSD outputs with test pulses that detect cross-faults, and a route where a single mechanical damage cannot affect both; the push-button follows ISO 13850. In materials, RoHS and REACH touch PVC and contact platings; and if the equipment goes into rail, EN 45545-2 demands fire behaviour and low smoke by hazard level (HL1-HL3), which rules out ordinary PVC and leads to EN 50264 or EN 50306 cables.

Cable: families, temperatures and colours

Wire is chosen by voltage, temperature, environment and, increasingly, by movement.

CableStandardVoltage · temperatureInsulationTypical use
UL 1007 / 1569UL 758 (AWM), CSA300 V · 80 / 105 °CPVCInternal signal and control, 16-30 AWG
UL 1015UL 758 (AWM), CSA600 V · 105 °CThick-wall PVCPower and mains in panels, 8-24 AWG
UL 1061UL 758 (AWM)300 V · 80 °CSemi-rigid PVC, thin wallDense harnesses, IDC
UL 3266 / 3271UL 758 (AWM)300 / 600 V · 125 °CXLPEHot zones, next to heaters and motors
H05V-K / H07V-KHAR, EN 50525300/500 V / 450/750 V · 70 °CPVCCabinet wiring in Europe; H07V2-K reaches 90 °C
LiYY / LiYCYManufacturer spec (VDE)≈ 300 V · 70-80 °CPVC; LiYCY with tinned braidControl and signal outside the cabinet
Servo / encoderDrive manufacturer spec600/1000 V · 80-90 °CShielded, PUR for carriersMotor, brake, resolver, encoder
FieldbusIEC 61158 and bus profilePer busPROFINET green 22 AWG · EtherCAT Cat 5e · PROFIBUS violet 150 Ω · CAN 120 Ω · IO-Link 3-wireCommunications, with their impedance and shield

Cross-section is stated in AWG in the UL world and in mm² in IEC; one convention is fixed per project so that 1.5 mm² and 16 AWG never share a drawing. IEC 60204-1 gives minimum cross-sections per function; the permissible current depends on bundling and cabinet temperature, not just on rated current. Servo cable is chosen by the capacitance per metre the drive tolerates: more capacitance, more leakage current and trips. For cable carriers the manufacturer declares a minimum bend radius and a cycle life (millions) for fine-stranded copper with a core filler and PUR sheath; fixed-installation cable is not designed for that.

On colours, IEC 60204-1 §13.2 mandates green-and-yellow for the protective conductor and light blue for the neutral, and recommends a code that almost all of European industry follows: black for AC and DC power, red for AC control, blue for DC control and orange for circuits that stay live when the main disconnect is opened. Another code is admissible if it is stated in the schematic. UL 508A uses a different convention (yellow for circuits fed from outside the panel), so a harness for both markets calls for an explicit decision.

Then there is the choice between single wires and sheathed multicore. In slotted trunking inside the cabinet, single wires win: they can be reassigned, identified and sized circuit by circuit. Outside the cabinet or in moving sections, multicore is better protected and passes cleanly through a cable gland. Almost every machine carries both, joined at terminal blocks or a rectangular connector.

Connectors: from M8 to Han, from DIN rail to PCB

A machine harness touches four connector scales: field, cabinet, power and board.

FamilyExamplesIPTypical currentUse
Miniature circularM8 (3-4 pins), M12 A-codedIP67; IP69K washdown≈ 3-4 ASensors, actuators, IO-Link, valves
Circular dataM12 D (100 Mbit/s), M12 X (1 Gbit/s), M12 B (PROFIBUS)IP67SignalPROFINET, EtherNet/IP, EtherCAT, cameras
Circular powerM12 L / S / T / K, M23, M40IP67M12 L up to 16 A; M23 tens of A; M40 large servosField power, servomotors; M23 signal for encoders
Industrial rectangularHarting Han A / E / Q / Modular; Phoenix Contact Heavycon; Weidmüller RockStarIP65 with hood; IP68/69K in specific rangesHan E 16 A per contact; modules up to 200 APluggable cabinet-to-machine harness; power + signal + bus + pneumatics
DIN-rail terminal blocksPhoenix Contact PT (push-in), Weidmüller A-series, Wago TOPJOB SInside the cabinetBy cross-section, 0.14 to 35 mm² and aboveBoundary between internal harness and field
PCB connectorsMolex Mini-Fit Jr. (4.2 mm), Micro-Fit 3.0; JST XH / PH / VH; TE AMP Mate-N-LokNo IPMini-Fit Jr. 9-13 A; Micro-Fit 5 A; JST XH 3 A, PH 2 A, VH 10 AControl electronics, HMI, PSUs, medical and laboratory equipment
DC and battery powerAnderson SB50 to SB350, Powerpole; Amphenol SurLok, RADSOKBy housing15 A to hundreds of AAGVs, industrial and agricultural vehicles, renewables
Ribbon and IDC1.27 mm ribbon with 2.54 mm IDCNo IP≈ 1 A per wayBoards, displays, membrane keypads

In M12 the coding keys are mechanically different: A for sensors and IO-Link, D for 100 Mbit/s Ethernet with 4 pins, X for Gigabit with 8 pins and individually shielded pairs, and L, S, T or K for power; IP69K only makes sense with pressure washdown (food, pharma). In Harting Han the insert sets poles and current (Han E is the workhorse: 16 A, up to 48 poles; Han A is compact; Han Q packs power into few poles; Han-Modular takes power, signal, RJ45, coaxial, fibre or pneumatic modules in the same housing), while the housing (3A to 24B) and hood set IP rating, cable exit and locking. Push-in terminal blocks accept ferruled wire without a tool, which makes crimping DIN 46228 ferrules the most repeated operation on a cabinet harness; spade and ring terminals call for a calibrated crimper and a pull test. Cable glands set the real IP of the assembly: an IP67 M12 on a box with the wrong gland leaves the box at IP54. Hybrid connectors (power and data in one cable) shrink the harness but tie the design to one manufacturer.

Protection, routing and EMC

Inside the cabinet the harness runs in lidded slotted trunking, not overfilled. Towards the machine the usual choices are polyamide corrugated conduit (PA6, typically -40 to +105 °C, oil-resistant), PET braided sleeving (abrasion, no IP), spiral wrap for sections that must be opened, heat-shrink 2:1 or 3:1 with adhesive at exposed connector exits, and UV-stabilised cable ties with mounts outdoors.

The cable carrier has rules of its own: respect the minimum radius of the most demanding cable, leave clearance around each cable, distribute weight symmetrically, separate power and signal with dividers and fix the cables only at both ends, never in the flexing section. EMC separation follows the same logic across the machine: power and signal in separate trunking, crossings at 90°, servo, encoder and bus shields terminated over 360° with EMC clamps on an earth bar at the cabinet entry, never as a pigtail, and a functional earth made with flat bar or braid. At cabinet doors the harness crosses the hinge with excess length, protected by spiral or conduit, and with its own green-and-yellow bonding conductor.

Mistakes that keep coming back. Servo and encoder in the same carrier cell. A shield finished as a ten-centimetre pigtail to any handy terminal. Cable ties cinched until the pairs of a data cable deform. Unmarked wire in a "small" panel that later grows. Cross-section sized for rated current without counting the twenty wires bundled together at 45 °C. None of them shows on the schematic; all of them show up at commissioning.

Identification and labelling

IEC 60204-1 requires every conductor to be identifiable at both ends in accordance with the technical documentation. In machinery this is solved with wire marking by number or by function, identical at both ends and in the schematic: printed heat-shrink sleeves for wires going to connectors, clip-on markers (Partex type) and self-laminating labels for sheathed cables, printed with Brady, Phoenix Contact (Thermomark) or Weidmüller (PrintJet) systems that read the project's wire list. Terminal, device and connector references follow IEC 81346 (clause 16 of 60204-1). Regulated equipment adds lot traceability: harness serial number, cable and terminal lot, operator and date, kept with the drawing revision.

Process: from the from-to list to production and service

It starts with the connection diagram or the from-to list: every wire with origin, destination, cross-section, colour and function, using device references to IEC 81346 (for example +A1-X1:3: cabinet A1, terminal strip X1, terminal 3). Lengths come from the cabinet and machine layout: the real run through trunking with the excess at doors and carriers, not straight-line distance. From that the 1:1 formboard is built so the shop cuts, marks and tapes without measuring each wire.

Minimum verification is continuity and absence of crosses against the connection table; for mains circuits, dielectric strength and insulation; for safety, separated channels. Revision control is tied to the machine's: every commercial option is a harness variant with its own drawing and every change bumps the revision in the title block. Documentation has two readers: production wants the formboard, cut list and BOM; after-sales wants the connection table readable at the machine, because ten years later someone will replace a sensor without the designer at hand.

Mapping

Every industrial harness need, and the feature that answers it

harnessPRO documents the harness; electrical calculation and cross-section choice remain the engineer's job.

Schematic with multipole connectors (24-pole Han, 5-pin M12), terminals, splices and bus pairs
Schematic view. Connectors with cavities, splices, twisted pairs, diodes and resistors; the netlist is built as you draw.
1:1 formboard of the harness that crosses the machine, with branches to every motor and sensor
Layout view at 1:1 scale. Branch points, boots orientable by type, manual routing and coloured groups to keep power and signal apart.
Real lengths from the cabinet drawing or a photo of the machine
Background image in Schematic and Layout. Load the drawing or photo and trace over it; lengths are documented wire by wire.
Bring in real M12, Han, Molex and terminal blocks with their cavities, gender and manufacturer
Digi-Key catalogue and pinout import. The part number arrives with cavities, gender, manufacturer and price; the manufacturer's pinout table is imported onto the connector.
Purchase list for the ERP and the shop: cable, terminals, ferrules, connectors, sleeving
BOM to CSV / Excel. Library parts aggregated with quantities, ready for purchasing.
Drawing for production and after-sales with the connection table, per machine variant
PDF drawings with title block and revisions. Connection tables, lengths and gauges in the PDF; revisions keep each variant with its drawing.
Engineering office and shop floor on the same harness, with no coverage in the hall
Cloud account with offline editing. The same harness on any device; without a connection you keep editing and it syncs when you are back. Team plan for several users.
Workflow

From the from-to list to the shop drawing in four steps

01 · SCHEMATIC

Draw the connection diagram

Place the cabinet Han, the field M12s, the terminal strips and the splices; connect wire by wire with cross-section, IEC 60204-1 colour and device tag.

02 · LAYOUT 1:1

Build the formboard over the drawing

Load the cabinet or machine drawing as a background, place the branch points and route the harness along its real path with the door and carrier excess.

03 · PARTS / BOM

Assign real components

Bring connectors and terminals from Digi-Key or the library, import pinouts, add cable, sleeving and ferrules. Export the BOM to CSV or Excel.

04 · DRAWINGS

Publish drawings per variant

Generate the PDF with title block, connection table and lengths; save one revision per machine option and share the account with the shop.

FAQ

Frequently asked questions about industrial wire harnesses

Which standard governs the wiring of a machine?

In Europe, IEC/EN 60204-1 (electrical equipment of machines): minimum cross-sections, conductor identification, colours, wiring practices and documentation, harmonised for CE marking. The harness as a product is accepted to IPC/WHMA-A-620 in the class the customer specifies. If the machine ships to North America, the panel is built to UL 508A with wire of a recognised type (AWM under UL 758, MTW, THHN).

Which wire colours does IEC 60204-1 require?

It mandates green-and-yellow for the protective conductor and light blue for the neutral. For the rest it recommends, without requiring: black for AC and DC power, red for AC control, blue for DC control and orange for circuits that stay live when the main disconnect is opened. Whichever code you choose must be documented in the schematic.

M12 A, B, D or X coding: which goes where?

A for sensors, actuators and IO-Link (3 to 12 pins). B for PROFIBUS DP. D for 100 Mbit/s industrial Ethernet (PROFINET, EtherNet/IP, EtherCAT), 4 pins. X for Gigabit, 8 pins with individually shielded pairs. L, S, T and K codings are for power. The mechanical keys differ and are not interchangeable.

Which Harting Han insert should I choose?

Han E is the workhorse in machinery: 16 A per contact, 6 to 48 poles. Han A is more compact, for a few signals. Han Q packs power into few poles, for example a motor with brake. Han-Modular mixes power, signal, bus, pneumatic or fibre modules in one housing. The housing (3A to 24B) and hood set the IP rating and the locking.

Which cable goes in a cable carrier?

Cable designed for continuous motion: fine-stranded copper in short lay lengths, a core filler, PUR sheath, a minimum bend radius and a cycle life declared by the manufacturer (millions). Servo and encoder cables must also be shielded and within the capacitance the drive accepts. A standard H05V-K or LiYY does not survive continuous flexing.

Open harness or sheathed multicore cable?

Inside the cabinet, in slotted trunking, single wires: they can be reassigned, identified and sized circuit by circuit. Outside the cabinet or in moving sections, sheathed multicore (LiYCY, servo cable, bus cable): better protected and clean through a cable gland. Almost every machine carries both, joined at terminal blocks or a Han connector.

Is harnessPRO suitable for machine and panel harnesses?

Yes. Schematic with multipole connectors, terminals, splices and twisted pairs; 1:1 Layout as a formboard with branch points and a background image of the cabinet drawing to take lengths from; real components (M12, Han, Molex) from Digi-Key or by importing the manufacturer's pinout; BOM to CSV/Excel and PDF drawings with connection tables; revisions per machine variant. It documents cross-sections and lengths, but does no electrical or thermal calculation.

Start with the harness for your next machine

Free Garage plan: 3 harnesses and 50 connections per harness, nothing to install. Pro and Team when the shop floor joins you. Prices include tax.